Should corrugated insert pieces be installed before or after applying perimeter adhesive beads on shipping container side walls?
Short answer
Corrugated insert pieces must be installed before applying perimeter adhesive beads and continuous panels to shipping container side walls. Gluing inserts into corrugation valleys first using a 3/8-inch bead creates a flat, solid backing that sits flush with interior steel ribs within a 1/16-inch tolerance. This proper sequence eliminates dead air cavities, prevents interior moisture condensation, and ensures the continuous insulation panels achieve full adhesive contact across the wall.
Corrugated insert pieces must always be glued into the steel wall recesses before applying adhesive to continuous insulation panels, creating a flush, solid substrate that ensures full adhesive contact and structural panel support.
Shipping container conversions across residential and commercial builds face severe thermal bridging through corrugated steel walls, which offer near-zero thermal resistance on their own. Filling the corrugation profiles eliminates dead air space behind the rigid insulation and provides a flat backing surface for subsequent interior wall panels.
If you only do one thing: Glue all vertical corrugated inserts into the container wall recesses first and verify they sit flush with the interior steel ribs before applying adhesive to the main panels.
- Surface preparation: Clean the interior steel sidewall with a wire brush and vacuum to remove loose scale, rust, and factory oils that weaken the adhesive bond.
- Insert gluing: Apply a 3/8-inch bead of approved construction adhesive to the back of each container insert and press the foam securely into every inward-facing corrugation valley.
- Substrate leveling: Check that the face of each installed insert sits flush with the adjacent interior metal ribs within a 1/16-inch tolerance, creating a uniform backing plane across the entire sidewall.
- Panel adhesive application: Run a continuous 3/8-inch bead of adhesive down the embedded studs on the back of each panel, adding a zig-zag bead across the foam contact surfaces where they meet the metal ribs and inserts.
- Panel installation: Press the 2x4-foot interlocking panels horizontally against the prepared wall, engaging the tongue-and-groove edges to establish continuous insulation across the container interior.
- Watch out for: Skipping inserts on 20-foot or 40-foot containers, which leaves trapped air cavities that foster condensation and reduce the panel's mechanical bond strength.
- Watch out for: Using solvent-based adhesive formulas instead of modified polyurethanes (such as Loctite PL Premium 3X), which melt the expanded polystyrene foam core.
- Watch out for: Applying oversized glue beads over 3/8 inch behind inserts, pushing the foam proud of the steel ribs and preventing panels from seating flush.
Calculate your sidewall square footage and corrugation valley count to determine insert quantities, or contact InSoFast technical support at (888) 501-7899 for project-specific takeoff assistance.
Explore related answers
- Shipping container interior and exterior insulation panel syShould side wall container inserts be glued in place before attaching the primary flat insulation panels?
- Shipping container interior and exterior insulation panel syIn what order should shipping container side walls, end walls, and ceilings be insulated using continuous panels?
- Shipping container interior and exterior insulation panel syDo container ceiling panels install before or after side wall continuous insulation?
- Shipping container interior and exterior insulation panel syDo shipping container ceiling corrugation profiles match the side wall corrugations for insert fitting?