Answers · Building code compliance documentation and physical testing

Will DrJ TER 1910-03 satisfy local building inspectors looking for ICC-ES equivalent evaluation reports?

Reviewed by InSoFastLast verified Nov 23, 20263 sources

Short answer

DrJ TER 1910-03 satisfies building inspectors seeking ICC-ES equivalent reports because DrJ Engineering is an accredited ISO/IEC 17065 certification agency. Under model building codes like IBC and IRC Section 104.11, building officials can approve alternative materials backed by accredited third-party reports. Submitting the complete report with your initial permit application confirms compliance for insulation, fire safety, and adhesive load values of over 800 pounds per linear foot.

Yes, DrJ TER 1910-03 satisfies local building officials because DrJ Engineering is an ISO/IEC 17065 accredited agency, establishing InSoFast panels as code-compliant alternatives equivalent to ICC-ES evaluation reports under IBC and IRC Section 104.11.

Building officials frequently ask for ICC-ES reports out of habit, unaware that model codes accept reports from any accredited third-party certification agency. Under Section 104.11 of the International Building Code (IBC) and International Residential Code (IRC), authorities having jurisdiction can approve alternative materials supported by duly authenticated reports verifying equivalency in structural strength, fire safety, effectiveness, and durability.

If you only do one thing: Submit the complete 20-page DrJ TER 1910-03 report with your initial permit application so the plans examiner can verify the ISO/IEC 17065 accreditation credentials up front.

  • Accreditation equivalency: DrJ Engineering is an ISO/IEC 17065 accredited certification body, giving Technical Evaluation Report (TER) 1910-03 the same legal and regulatory status as an evaluation report from ICC-ES.
  • Model code approvals: Report 1910-03 certifies InSoFast panels under the 2024, 2021, and earlier editions of the IBC, IRC, and International Energy Conservation Code (IECC) for continuous insulation performance.
  • Surface burning characteristics: The report documents compliance with ASTM E84 flame spread index (FSI ≤ 25) and smoke-developed index (SDI ≤ 450) limits under IBC Section 2603.3 and IRC Section R303.3.
  • Commercial assembly testing: Table 3 of TER 1910-03 approves specific exterior InSoFast wall configurations on concrete and CMU base walls under NFPA 285 for Type I, II, III, and IV construction.
  • Attachment load values: The evaluation verifies that continuous adhesive bonding with Loctite PL Premium provides over 800 pounds of holding force per linear foot of stud, matching mechanical concrete screw schedules spaced 6 inches on center.
  • Canadian recognition: The technical evaluation encompasses Canadian ULC standards and CAN/ULC-S102 testing, supporting code compliance across Canadian provincial jurisdictions.
  • Watch out for: Omitting the mandated 15-minute thermal barrier, as building codes still require 1/2-inch gypsum board over interior foam plastic insulation regardless of evaluation reports.
  • Watch out for: Using unapproved construction adhesives, which invalidates the certified 800-pound pull-off strength ratings outlined in the installation instructions.
  • Watch out for: Assuming TER 1910-03 provides hourly fire-resistance ratings, as hourly fire-rated separation assemblies fall outside the scope of Section 8.4 of the report.

Download the complete DrJ TER 1910-03 PDF from the InSoFast website and include it with your architectural submittals, or call InSoFast technical support at (888) 501-7899 for local inspector verification letters.