Under which CSI MasterFormat divisions and section numbers are InSoFast continuous insulation panels classified in building specifications?

Reviewed by InSoFastLast verified Nov 19, 20264 sources

Short answer

InSoFast continuous insulation panels are classified under CSI MasterFormat Division 07 00 00 for Thermal and Moisture Protection, specifically Section 07 21 13 for Foam Board Insulation and Section 07 21 00 for Thermal Insulation. Projects incorporating the X-Bracket system must additionally reference Section 07 77 00 for Wall Specialties. Architects should avoid listing panels under framing or carpentry divisions despite built-in studs, referencing engineering report TER 1910-03 for compliance.

InSoFast continuous insulation panels are officially classified under CSI MasterFormat Division 07 00 00 (Thermal and Moisture Protection), specifically under Section 07 21 00 (Thermal Insulation) and Section 07 21 13 (Foam Board Insulation).

Specifiers, commercial architects, and contractors require precise Construction Specifications Institute (CSI) MasterFormat numbering to prevent cross-trade bidding conflicts and misallocated installation scopes. Building envelope assemblies must clearly coordinate continuous insulation—insulation running uninterrupted across structural framing members to prevent thermal bridging—alongside drainage, vapor control, and interior substrate attachment within project manuals.

If you only do one thing: Specify InSoFast panel assemblies under Section 07 21 13 (Foam Board Insulation) while referencing Section 07 77 00 if incorporating the X-Bracket continuous insulation system.

  • MasterFormat Division 07 00 00: Thermal and Moisture Protection is the overarching division governing all InSoFast continuous insulation systems across interior basement walls, exterior framing, and shipping containers.
  • MasterFormat Section 07 21 00: Thermal Insulation defines the general performance criteria, code evaluations, and thermal testing for UX 2.0, EXi 2.5, EXe 2.5, MAX 3.75, and CX44 panels.
  • MasterFormat Section 07 21 13: Foam Board Insulation designates the primary product classification per DrJ Engineering Technical Evaluation Report (TER) 1910-03, covering closed-cell expanded polystyrene (EPS) rigid panels with embedded studs.
  • MasterFormat Section 07 77 00: Wall Specialties (under Section 07 70 00 for Roof and Wall Specialties and Accessories) applies specifically when specifying the InSoFast X-Bracket continuous insulation system evaluated under DrJ TER 2405-119.
  • Cross-Division Attachment: While integrated polypropylene studs eliminate separate framing, interior wall finishes attach directly over the studs under Division 09 29 00 (Gypsum Board) to provide the code-mandated 15-minute thermal barrier.
  • Watch out for: Classifying panels under Division 06 10 00 (Rough Carpentry) or Division 09 22 00 (Non-Structural Metal Framing); despite built-in studs spaced at 16 inches on center, code listings evaluate the full unit as rigid foam insulation under Division 07.
  • Watch out for: Omitting the 15-minute thermal barrier requirement in Division 09 29 00, which mandates covering interior foam plastics with minimum 1/2-inch gypsum drywall to meet building fire codes.
  • Watch out for: Omitting evaluation report numbers (DrJ TER 1910-03 for panel lines or TER 2405-119 for bracket accessories) on specification sheets submitted to local building authorities.

Cross-reference your project manual's Section 07 21 13 with DrJ Report 1910-03 to confirm design compliance and assembly load values before finalizing construction documents.