Under what DrJ Technical Evaluation Report number are InSoFast EPS panels listed for code compliance?
Short answer
InSoFast expanded polystyrene insulation panels are listed for nationwide building code compliance under DrJ Technical Evaluation Report number 1910-03. This report covers the UX 2.0, EXi 2.5, and container panel profiles, providing verified structural, thermal, and fire performance documentation for residential and commercial permitting. Referencing TER 1910-03 on permit submittal drawings confirms compliance for continuous insulation, stud fastening load capacities, and required interior thermal barrier assemblies.
InSoFast expanded polystyrene (EPS) insulation panels are listed for nationwide building code compliance under DrJ Engineering Technical Evaluation Report (TER) number 1910-03, covering the UX 2.0, EXi 2.5, and container panel profiles.
Building officials and specifiers require verified evaluation reports from accredited testing agencies to prove continuous insulation assemblies meet International Building Code (IBC) and International Residential Code (IRC) standards. TER 1910-03 provides the structural, thermal, and fire performance documentation needed for residential and commercial permitting across the United States.
If you only do one thing: Reference DrJ TER 1910-03 on your permit submittal drawings to establish code compliance for continuous insulation, stud fastening load ratings, and thermal barrier assemblies.
- Accredited evaluation body: DrJ Engineering, LLC conducts listings as an ANAB ISO/IEC 17065 accredited evaluation agency, establishing code equivalency recognized under model building code provisions for alternative materials and methods.
- Evaluated panel profiles: Report 1910-03 covers injection-molded EPS panels, including the 2.0-inch thick UX 2.0 panel and the 2.5-inch thick EXi 2.5 profile.
- Integrated stud fastening: The testing evaluates the load capacity and fastener pull-out strength of the co-molded polypropylene framing studs spaced 16 inches on-center, which eliminate traditional wood and steel thermal bridging.
- Thermal barrier requirements: The evaluation confirms standard compliance when the EPS foam is separated from the building interior by an approved 15-minute thermal barrier, such as 1/2-inch gypsum drywall fastened directly to the studs.
- Distinct bracket reports: Heavy-duty secondary continuous framing products carry separate evaluations; the InSoFast X-Bracket system is cataloged independently under DrJ TER number 2405-119.
- Watch out for: Submitting the wrong report number for exterior bracket installations, because standalone bracket hardware requires referencing TER 2405-119 rather than panel report TER 1910-03.
- Watch out for: Failing to specify the code-mandated 1/2-inch gypsum drywall over exposed interior foam installations in occupied basements and container conversions to satisfy the 15-minute thermal barrier requirement.
- Watch out for: Using powder-actuated nail guns during concrete installation, which can crack the polymer framing studs; use approved construction adhesive or mechanical concrete screws spaced 12 inches on-center instead.
Download the complete PDF of DrJ TER 1910-03 from the technical documentation directory to include with your architectural plans and permit filing packet.