Answers · Building code compliance documentation and physical testing

Under which DrJ Engineering technical evaluation report number are UX and EX panels certified for code compliance?

Reviewed by InSoFastLast verified Nov 18, 20263 sources

Short answer

InSoFast UX 2.0 and EX 2.5 continuous insulation panels are certified for nationwide building code compliance under DrJ Engineering Technical Evaluation Report number 1910-03. This accredited report provides building officials with verified proof that the panels satisfy residential and commercial building codes in the United States and Canada. Submitting this document with permit drawings validates continuous insulation performance, fire barrier requirements, and built-in stud fastening capacity across wall assemblies.

InSoFast UX 2.0 and EX 2.5 continuous insulation panels are certified for nationwide building code compliance in the United States and Canada under DrJ Engineering Technical Evaluation Report number 1910-03.

Building code officials and specifiers require third-party evaluation reports to verify that composite wall assemblies satisfy International Building Code (IBC) and International Residential Code (IRC) standards. Under model building codes, accredited third-party engineering reports establish verified proof for continuous insulation, structural fastening capacity, and fire barrier compliance.

If you only do one thing: Submit DrJ Engineering TER 1910-03 with your permit drawings to establish direct code equivalency with ICC-ES standards across residential and commercial jurisdictions.

  • Report scope: DrJ TER 1910-03 evaluates InSoFast expanded polystyrene panels, including UX 2.0 and EX 2.5, for interior basements, above-grade walls, concrete ceilings, floors, and shipping containers.
  • Accreditation standard: DrJ Engineering is an ANAB ISO/IEC 17065 accredited evaluation body, qualifying it as an approved agency to issue technical reports under model building codes.
  • Code equivalency: The technical evaluation establishes equivalency with ICC-ES evaluation services, certifying compliance with model IBC and IRC codes alongside Canadian National Building Code and ULC standards.
  • Thermal performance: The evaluation verifies continuous thermal insulation specifications, certifying UX 2.0 at continuous R-8.5 and EX 2.5 at continuous R-10 without thermal bridging.
  • Attachment capacity: The report documents the engineered pull-out and shear load ratings for the built-in polypropylene studs spaced 16 inches on center, supporting direct screw fastening of 1/2-inch drywall.
  • Watch out for: Confusing general insulation panel report TER 1910-03 with DrJ TER 2405-119, which specifically evaluates the continuous insulation X-Bracket system.
  • Watch out for: Omitting the code-mandated 15-minute thermal barrier, which requires covering interior expanded polystyrene foam with 1/2-inch drywall or an approved equivalent.
  • Watch out for: Installing mechanical fasteners on concrete without following the verified 12-inch on-center spacing schedule outlined in the manufacturer technical specifications.

Download the complete DrJ TER 1910-03 evaluation document from InSoFast or call technical support at (888) 501-7899 to obtain the official engineering submittal packet for your local building department.