What permeability of vapor barrier should be used on exterior of plywood on 2x4 frame wall, which will have 7.25 in. bat brackets mineral wool followed by a 1-inch air gap and brick veneer wall. Also what perm to use on outside of mineral wool?

Reviewed by InSoFastLast verified Nov 13, 20264 sources

Short answer

Install a vapor-permeable weather-resistive barrier rated between 10 and 20 perms directly over the plywood sheathing, and use a high-permeability breather membrane rated above 50 perms if wrapping the exterior face of the mineral wool.

Install a vapor-permeable weather-resistive barrier rated between 10 and 20 perms directly over the plywood sheathing, and use a high-permeability breather membrane rated above 50 perms if wrapping the exterior face of the mineral wool.

Brick veneer acts as a reservoir cladding, storing bulk rainwater that solar radiation drives inward toward the framing cavity as vapor. With 7.25 inches of exterior mineral wool (R-25 to R-30) installed via Batt-Brackets, the plywood sheathing stays above the interior dew point across Climate Zones 1 through 8 under the 2024 International Residential Code (IRC), shifting moisture control to continuous outward drying and cavity ventilation.

If you only do one thing: Keep the outer face of the mineral wool above 50 perms and maintain an unobstructed 1-inch clear air cavity with open weep vents spaced at 24 inches on center.

  • Primary Sheathing WRB (10–20 Perms): Apply a self-adhered or liquid-applied Water-Resistive Barrier (WRB) directly to the exterior face of the plywood to serve as your primary continuous air barrier and drainage plane while permitting moisture inside the wall cavity to dry outward.
  • 7.25-Inch Batt-Bracket Installation: Mount 7.25-inch InSoFast Batt-Brackets over the WRB into the 2x4 framing to hold 16¼-inch or 24¼-inch wide steel-stud-width mineral wool batts, securing continuous insulation without conductive thermal bridging.
  • Mineral Wool Exterior Face (>50 Perms): Mineral wool itself is naturally vapor-open at over 30 to 50 perms per inch; if using an exterior housewrap over the insulation to protect against wind-washing and mortar contact, use a micro-perforated or spun-bonded polypropylene sheet rated at 50 perms or higher.
  • 1-Inch Ventilated Drainage Gap: Maintain a continuous 1-inch clear air space between the exterior surface of the mineral wool assembly and the backside of the brick veneer to provide capillary break isolation and buoyancy-driven airflow.
  • Base Flashing and Cavity Weeps: Terminate the drainage plane onto self-adhering through-wall flashing at the wall base, directing water outward through open head-joint weep vents spaced 24 inches on center.
  • Watch out for: Installing a low-perm polyethylene or foil facer on the outside of the mineral wool, which traps inward-driven solar vapor inside the continuous insulation layer.
  • Watch out for: Mortar bridges dropping into the 1-inch gap during brick installation, which blocks drainage paths and transfers capillary moisture directly to the insulation.
  • Watch out for: Adding an interior Class I vapor barrier (such as 6-mil poly) on the interior face of the 2x4 studs in mixed or warm climates, creating a double vapor barrier that traps framing moisture.

Confirm your local energy code requirements under IRC Section R702.7 for exterior insulation ratios, then tape and seal all primary WRB seams over the plywood before fastening your Batt-Bracket system.